1. Antix Rapid Cassette Test for Clenbuterol -- A rapid chromatographic immunoassay for the detection of Clenbuterol
Intended Use
Antix Rapid Cassette Test for Clenbuterol is a colloidal
gold labelled antibody complex based competitive
immunoassay designed for qualitative determination
of the clenbuterol in unknown samples.
It is intended for determination clenbuterol if the urine
sample contains more than 3ppb.
Specifications
| Kits format |
40 tests. |
| Reaction time |
5-10min (regardless of time of samples treatment). |
| Sample preparation |
Urine specimen can be directly used in the test.
Tissue, meat, liver and animal feed should be treated. |
| Volume of sample |
75ul. |
| Detection limit |
3ppb (3ug/Kg), depending on the sample. |
| Accuracy |
95 % ± 3% |
2.Antix One Step Aflatoxin Cassette Test -- A rapid chromatographic immunoassay for the detection of Aflatoxin
Intended use
Antix One Step Aflatoxin cassette test is a colloidal
gold antibody complex based competitive immunoassay
designed for the qualitative determination of the
aflatoxin in unknown samples. It is intended for determination
if the unknown sample contains more than 5ppb.
Specifications
| Kits format |
40 tests. |
| Reaction time |
10min. (regardless of time of samples treatment). |
| Sample preparation |
Homogenization and extraction. |
| Volume of sample |
75ul. |
| Detection limit |
5ppb (5ug/Kg), depending on the sample. |
| Accuracy |
94 % ±4% |
3. Antix Clenbuterol EIA Kits -- Enzyme immunoassay for the quantitative analysis of Clenbuterol
Intended use
The Antix Clenbuterol kit is a competitive enzyme immunoassay
for the quantitative analysis of clenbuterol in urine, muscle,
liver, cattle eyeball, and also animal food. The range of
quantitative is between 0.1ppb (0.1ug/Kg) and 8.1ppb (8.1ug/Kg).
Specifications
| Microtiterplate format |
96 well |
| Reaction time |
50min(regardless of time
of samples treatment) |
| Sample preparation |
homogenisation, extraction,
centrifugation and reduction to dryness |
| Detection limit |
0.1ppb (0.1ug/Kg), depending on the sample. |
| Recovery rate |
91 % ± 15%. |
| Cross reaction |
| clenbuterol |
100.0% |
mabuterol |
100.0% |
| brombuterol |
150.0% |
carbuterol |
4.0% |
| terbutalin |
100.0% |
isoproterenol |
<0.1% |
| salbutamol |
10.0% |
adrenalin |
<0.01% |
| cimaterol |
6.0% |
noradrenalin |
<0.01% |
|
| Samples per kit |
Up to 42 tests. |
| Standards |
0 / 0.1 / 0.3 / 0.9 / 2.7 / 8.1 ppb. |
| Measurement |
Microtiter plate reader (450 nm). |
4. Antix Aflatoxin EIA Kit -- Enzyme immunoassay for the quantitative analysis of Aflatoxin B1
Intended use
Antix Aflatoxin Kit is a quantitative test that can be used to
determine the approximate concentrations of aflatoxin B1
in an unknown sample. The range of quantitative is between
0.1ppb (0.1ug/Kg) and 8.1ppb (8.1ug/Kg).
Specifications
| Microtiter plate format |
96 well. |
| Reaction time |
45min (regardless of time of samples treatment). |
| Sample preparation |
Extraction using methanol. |
| Detection limit |
0.1ppb (0.1ug/Kg), depending on the sample. |
| Recovery rate |
>85% for all samples. |
| Samples per kit |
Up to 42 tests |
| Standards |
0 / 0.1 / 0.3 / 0. 9/ 2.7 / 8.1ppb. |
| Measurement |
Microtiter plate reader (450 nm). |
5.Antix Chloramphenicol EIA Kits -- Enzyme Immunoassay for the Quantitative Determination of Chloramphenicol
Intended use
The Antix Chloramphenicol kit is a competitive enzyme
immunoassay for the quantitative analysis of chloramphenicol
residues in milk, milk powder, meat and eggs, mixed feed,
shrimps, fishmeal, honey and urine et al. The range of
quantitative is between 0.05ppb (0.05ug/Kg) and 4.05ppb (4.05ug/Kg).
Specifications
| Microtiterplate format |
96 well |
| Reaction time |
50min(regardless of time
of samples treatment) |
| Sample preparation |
Homogenization, extraction, centrifugation and reduction to dryness. |
| Detection limit |
0.05ppb (0.05ug/Kg), depending on the sample. |
| Recovery rate |
85%± 21%. |
| Cross reaction |
| chloramphenicol |
100.0% |
chloramphenicol-Base |
< 0.5 % |
| thiamphenicol |
< 0.05 % |
ampicillin |
< 0.01 % |
| penicillin |
< 0.01 % |
tetracyclin |
< 0.01 % |
| cephalothin |
< 0.01% |
erythromycin |
< 0.01% |
| doxycycline |
< 0.01% |
gentamycin |
< 0.01% |
|
| Samples per kit |
Up to 42 tests. |
| Standards |
0 / 0.05 / 0.15 / 0.45 / 1.35 / 4.05ppb. |
| Measurement |
Microtiter plate reader (450 nm). |
|
|