1. Antix Rapid Cassette Test for Clenbuterol -- A rapid chromatographic immunoassay for the detection of Clenbuterol

Intended Use
Antix Rapid Cassette Test for Clenbuterol is a colloidal gold labelled antibody complex based competitive immunoassay designed for qualitative determination of the clenbuterol in unknown samples. It is intended for determination clenbuterol if the urine sample contains more than 3ppb.


Specifications
Kits format 40 tests.
Reaction time 5-10min (regardless of time of samples treatment).
Sample preparation Urine specimen can be directly used in the test. Tissue, meat, liver and animal feed should be treated.
Volume of sample 75ul.
Detection limit 3ppb (3ug/Kg), depending on the sample.
Accuracy 95 % ± 3%

2.Antix One Step Aflatoxin Cassette Test -- A rapid chromatographic immunoassay for the detection of Aflatoxin

Intended use
Antix One Step Aflatoxin cassette test is a colloidal gold antibody complex based competitive immunoassay designed for the qualitative determination of the aflatoxin in unknown samples. It is intended for determination if the unknown sample contains more than 5ppb.

Specifications
Kits format 40 tests.
Reaction time 10min. (regardless of time of samples treatment).
Sample preparation Homogenization and extraction.
Volume of sample 75ul.
Detection limit 5ppb (5ug/Kg), depending on the sample.
Accuracy 94 % ±4%

3. Antix Clenbuterol EIA Kits -- Enzyme immunoassay for the quantitative analysis of Clenbuterol

Intended use
The Antix Clenbuterol kit is a competitive enzyme immunoassay for the quantitative analysis of clenbuterol in urine, muscle, liver, cattle eyeball, and also animal food. The range of quantitative is between 0.1ppb (0.1ug/Kg) and 8.1ppb (8.1ug/Kg).

Specifications

Microtiterplate format 96 well
Reaction time 50min(regardless of time of samples treatment)
Sample preparation homogenisation, extraction, centrifugation and reduction to dryness
Detection limit 0.1ppb (0.1ug/Kg), depending on the sample.
Recovery rate 91 % ± 15%.
Cross reaction
clenbuterol 100.0% mabuterol 100.0%
brombuterol 150.0% carbuterol 4.0%
terbutalin 100.0% isoproterenol <0.1%
salbutamol 10.0% adrenalin <0.01%
cimaterol 6.0% noradrenalin <0.01%
Samples per kit Up to 42 tests.
Standards 0 / 0.1 / 0.3 / 0.9 / 2.7 / 8.1 ppb.
Measurement Microtiter plate reader (450 nm).

4. Antix Aflatoxin EIA Kit -- Enzyme immunoassay for the quantitative analysis of Aflatoxin B1

Intended use
Antix Aflatoxin Kit is a quantitative test that can be used to determine the approximate concentrations of aflatoxin B1 in an unknown sample. The range of quantitative is between 0.1ppb (0.1ug/Kg) and 8.1ppb (8.1ug/Kg).

Specifications

Microtiter plate format 96 well.
Reaction time 45min (regardless of time of samples treatment).
Sample preparation Extraction using methanol.
Detection limit 0.1ppb (0.1ug/Kg), depending on the sample.
Recovery rate >85% for all samples.
Samples per kit Up to 42 tests
Standards 0 / 0.1 / 0.3 / 0. 9/ 2.7 / 8.1ppb.
Measurement Microtiter plate reader (450 nm).


5.Antix Chloramphenicol EIA Kits -- Enzyme Immunoassay for the Quantitative Determination of Chloramphenicol

Intended use
The Antix Chloramphenicol kit is a competitive enzyme immunoassay for the quantitative analysis of chloramphenicol residues in milk, milk powder, meat and eggs, mixed feed, shrimps, fishmeal, honey and urine et al. The range of quantitative is between 0.05ppb (0.05ug/Kg) and 4.05ppb (4.05ug/Kg).

Specifications

Microtiterplate format 96 well
Reaction time 50min(regardless of time of samples treatment)
Sample preparation Homogenization, extraction, centrifugation and reduction to dryness.
Detection limit 0.05ppb (0.05ug/Kg), depending on the sample.
Recovery rate 85%± 21%.
Cross reaction
chloramphenicol 100.0% chloramphenicol-Base < 0.5 %
thiamphenicol < 0.05 % ampicillin < 0.01 %
penicillin < 0.01 % tetracyclin < 0.01 %
cephalothin < 0.01% erythromycin < 0.01%
doxycycline < 0.01% gentamycin < 0.01%
Samples per kit Up to 42 tests.
Standards 0 / 0.05 / 0.15 / 0.45 / 1.35 / 4.05ppb.
Measurement Microtiter plate reader (450 nm).

 
  ©Copyright Antix Biotech Inc. 2007 All rights reserved